| Technical data |
| Title |
Value |
| Hot/cold water connections |
22mm compression |
| Height (mm) |
850 |
| Width (mm) |
600 |
| Depth (mm) |
600 |
| Weight |
112kg |
| DHW flow rate @ 35°C rise |
20 |
| Output to central heating |
7.4 - 29.2kw |
| Maximum horizontal flue (100mm Ø) |
4,000 |
| Maximum vertical flue (100mm Ø) |
6,400 |
| Maximum horizontal flue (125mm Ø) |
13,000 |
| Maximum vertical flue (125mm Ø) |
15,000 |
| Condensate disposal pump |
Yes |
| Gas connection |
22mm compression |
| Pressure relief valve |
15 |
| Heating flow and return connections |
22mm compression |
| Condensate connection |
22mm plastic pipe |
| Primary water content |
51L |
| NOx class |
Class 5 |
| Floor mounted pre-plumbing jig |
Yes |
| Fault diagnostic display |
Digital |
| Plug-in timers |
Yes (Optional) |
| Night set back module |
Yes (Optional) |
| Optimising room temperature controller |
Yes (Optional) |
| SEDBUK value %/band - natural gas |
90.8%/Band A |
| SEDBUK value %/band - LPG |
92.2%/Band A |
| Min. domestic inlet pressure for max. DHW flow rate (bar) |
1.5 |
| Min. domestic inlet pressure to operate the appliance (bar) |
0.5 |
| Max. domestic inlet pressure (bar) |
10 |
| Filling Link |
Yes |