Technical data
Title Value
Height (mm) 855mm
Width (mm) 370mm
Depth (mm) 600mm
Weight 118kg
SEDBUK Value/band 94.2% Band A
Solar compatible Yes
Burner Riello RDB 2.2
Minimum diameter flue CF 130mm (can be 100mm when using Worcester flexi-flue kit)
Minimum diameter flue RS 80/125, 100/150
Primary vent 1¼ inch BSP
Primary cold feed 3/4 inch BSP
Heating flow and return connections 28mm
Condensate connection 21.5
Condensate trap Accessory kit supplied
Oil connection 10
Max. primary static head 30
Min. primary static head 01
Primary water content 28
NOx class Class 3, 156mg/kWh
Available pump head 20°C 4.1 mH2O
Exhaust flue gas mass flow 51
Control thermostat differential 55/81
Power consumption 265
Ingress protection rating IP20
Flue reset overheat thermostat (cut out) (°C) 110
Boiler manual reset overheat thermostat (cut out) 105
Boiler high limit thermostat (cut out) (°C) 95
Max. horizontal flue RS 80/125 (mm) 4,000
Max. vertical flue RS 80/125 (mm) 8,000
Maximum hearth temperature <100
Power supply 230V, 50Hz