Greensource Air to Water Heat Pump 7kW Technical data table
| Technical data | |
|---|---|
| Title | Value |
| Dimensions w x h x d (mm)* | 818 x 1,223 x 643 |
| Weight (kg) | 144 |
| Outer casing | Galvanised powder coated steel |
| Emitted/supplied output at +7/35°C | 7.2/2.2 |
| Heat output / COP -7/35°C 1 | 5.0/2.3 |
| Heat output / COP 2/35°C 1 | 6.1/2.8 |
| Heat output / COP 7/35°C 1 | 7.2/3.3 |
| Heating system flow nominal l/s | 0.29 |
| Internal pressure drop heat carrier (kPa) | 6 |
| Air flow (m3)/h | 2,200 |
| Electrical consumption fan (A) | 0.44 |
| Fuse size - Amperes time delay 4 | 25 |
| Starting current - softstart (A) | 30.56 |
| Electrical supply | 230V 1N ~ 50Hz |
| Compressor | Scroll |
| Compressor oil | FV50S |
| Maximum outgoing flow temperature (°C) | 65 |
| Refrigerant filling R-407C (kg) | 2.6 |
| Defrost system | Hot gas with four way valve |
| Operating temperature (°C) 5 | -20 to +35 |
| HTF connection, clamping ring (mm) | Hose 1" internal thread |
| Sound power level (dB(A)) 2 | 65 |
| Sound pressure level (dB(A)) 3 | 53 |
| I.P. rating | x4 |
* Without feet, additionally depending on the adjustment min. 20mm - max. 30mm
Technical data notes
- Output data at +7/35°C, +7/45°C are stated according to the European Standard EN 14511
- Calculated value at 1m distance according to EN ISO 3743-2
- Calculated value at 1m distance according to EN ISO 11203
- aM type fuse, D characteristic McB
COPs are calculated using EN 14511 which includes the compressor and all pumps. It replaces BS EN 255 which excludes the above.


Social media