Greensource Air to Water Heat Pump 7kW Technical data table

Technical data
Title Value
Dimensions w x h x d (mm)* 818 x 1,223 x 643
Weight (kg) 144
Outer casing Galvanised powder coated steel
Emitted/supplied output at +7/35°C 7.2/2.2
Heat output / COP -7/35°C 1 5.0/2.3
Heat output / COP 2/35°C 1 6.1/2.8
Heat output / COP 7/35°C 1 7.2/3.3
Heating system flow nominal l/s 0.29
Internal pressure drop heat carrier (kPa) 6
Air flow (m3)/h 2,200
Electrical consumption fan (A) 0.44
Fuse size - Amperes time delay 4 25
Starting current - softstart (A) 30.56
Electrical supply 230V 1N ~ 50Hz
Compressor Scroll
Compressor oil FV50S
Maximum outgoing flow temperature (°C) 65
Refrigerant filling R-407C (kg) 2.6
Defrost system Hot gas with four way valve
Operating temperature (°C) 5 -20 to +35
HTF connection, clamping ring (mm) Hose 1" internal thread
Sound power level (dB(A)) 2 65
Sound pressure level (dB(A)) 3 53
I.P. rating x4

* Without feet, additionally depending on the adjustment min. 20mm - max. 30mm

Technical data notes

  1. Output data at +7/35°C, +7/45°C are stated according to the European Standard EN 14511
  2. Calculated value at 1m distance according to EN ISO 3743-2
  3. Calculated value at 1m distance according to EN ISO 11203
  4. aM type fuse, D characteristic McB

COPs are calculated using EN 14511 which includes the compressor and all pumps. It replaces BS EN 255 which excludes the above.