Can I use plastic pipework on oil fired sealed central heating systems?
For Greenstar condensing oil boilers
Plastic pipework is allowed to be used on oil boilers, provided there is at least 1000mm copper pipe connection to the boiler before any plastic.
Plastic pipework may also be used on under floor heating systems in conjunction with a blending valve.
Standard efficiency boilers
Standard efficiency boilers cannot use plastic pipe on their systems as they run at a higher operating temperature.